News & Videos

Home / News / news / What are the characteristics of the load bank?

What are the characteristics of the load bank?

Views: 0     Author: Site Editor     Publish Time: 2021-09-06      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

The load bank is a kind of power detection equipment, mainly for load detection and maintenance of generators, uninterruptible power supplies (ups), and power transmission equipment. It is a tool and equipment for periodic testing and maintenance of generator sets and UPS uninterruptible power supplies. The following is an introduction to the characteristics of the load bank.


load bank


Here is the content:

Adjustable power

Time can be set

Screen display data

Safety

Full functioning

Can work for a long time


Adjustable power

The load bank can be set to adjust the discharge power according to performance parameters and testing requirements. The power of ABC three-phase resistive load, inductive load, and capacitive load can be independently controlled and adjusted in phases, to accurately adjust the AC resonance point under the condition of unbalanced three-phase voltage. According to the performance parameter test requirements, the corresponding power of the load bank can be set through the operation panel or remote console, and the discharge power can be set in any combination. The minimum standard power of the resistive load, inductive load, and capacitive load of the load bank is 0.01K, the step amplitude is 0.01K, and the load power is continuously adjustable, which can accurately simulate the occurrence of AC resonance and meet the detection needs of the inverter's anti-islanding protection function.


Time can be set

The load bank can set the discharge time, and the load will be automatically turned off when the time is up.


Screen display data

The digital meter displays parameter values such as voltage and current. The ABC three-phase inductive current value and the ABC three compatible current value are directly and independently displayed on the control panel, and the AC resonance point symptom is directly displayed on the panel.


Safety

The load bank machine adopts new power consumption components and has the protection function of automatically blocking overheating. Each branch of the load bank’s built-in capacitive load must be equipped with a special protection circuit module for short-circuit prevention to prevent the capacitor element from short-circuiting and burning the host during the test process. The resistive load adopts alloy resistance elements, and the resistance value thermal drift will not be caused by the heating of the resistive load element during the test process.


Full functioning

The load bank has various specifications and a complete series. There are pure resistive loads or resistive, inductive, and capacitive loads.


Can work for a long time

The built-in capacitor of the load bank adopts the UL certification standard CBB capacitor, which meets the 0.01KVAR power adjustment requirements under 220V/50Hz working conditions, and meets the long-term load test process. The capacitor impedance power will not change. The built-in inductance of the load bank adopts a magnetic circuit-type controllable load inductive load element, which meets the 0.01KVA power adjustment requirements under 220V/50Hz working conditions, and meets the long-term load test process. The inductive impedance power will not change.


All Mecca Power products undergo several experiments before they leave the factory. Our website is https://www.meccapower.com.cn. If you are engaged in load bank-related work, you can contact us on the website.


Quick Links
Contact Us
  +86-156-5999-4455
  +86-591-83053902
Copyright 2020 Mecca Power All Rights Reserved.